Sv1ProductType#
- class Sv1ProductType(value)[source]#
Bases:
ListEnum
This is the processing level of SuperView-1 data See
http://en.spacewillinfo.com/uploads/soft/210106/8-210106153503.pdf
file for more information.Note: Stereo product are not handled.
- classmethod convert_from(to_convert: list | str) list #
Convert from a list or a string to an enum instance
- Parameters:
to_convert (Union[list, str]) – List or string to convert into an enum instance
- Returns:
Converted list
- Return type:
Example
>>> TsxPolarization.convert_from(["SINGLE", "S", TsxPolarization.QUAD]) [<TsxPolarization.SINGLE: 'S'>, <TsxPolarization.SINGLE: 'S'>, <TsxPolarization.QUAD: 'Q'>]
- classmethod from_value(val: Any) ListEnum #
Get the enum class from its value:
- Parameters:
val (Any) – Value of the Enum
- Returns:
Enum with value
- Return type:
ListEnum
Example
>>> TsxPolarization.from_value("Q") <TsxPolarization.QUAD: 'Q'>
- classmethod list_names() list #
Get the name list of this enum:
Example
>>> TsxPolarization.list_values() ["SINGLE", "DUAL", "QUAD", "TWIN"]
- classmethod list_values() list #
Get the value list of this enum
Example
>>> TsxPolarization.list_values() ["S", "D", "Q", "T"]
- L1B = 'Basic Product'#
Basic Products are radiometrically corrected and sensor corrected, but not geometrically corrected or projected to a plane using a map projection or datum. The sensor correction blends all pixels from all detectors into the synthetic array to form a single image. The main radiometric processing includes: - Relative radiometric response between detectors; - Correction of differences in sensitivity between the detectors;
The sensor corrections include: - Internal detector geometry; - Optical distortion correction; - Registration of the panchromatic and multispectral bands
- L2A = 'Ortho Ready Standard Product'#
Ortho Ready Standard Products are radiometrically corrected, sensor corrected, and projected to a ellipsoid using current image mean elevation for each panchromatic and multispectral. All Ortho Ready Standard Products can have a uniform GSD throughout the entire product. The default projection is UTM projection. Ortho Ready Standard Products are available in panchromatic at 0.5 meters and multi-spectral bands at 2 meters. The radiometric corrections applied to the Ortho Ready Standard Product include relative radiometric response between detectors and non-responsive detectors. The sensor corrections include internal detector geometry, optical distortion, scan distortion, any line-rate variations, and registration of the panchromatic and multispectral bands. Geometric corrections remove spacecraft orbit position and attitude uncertainty, Earth rotation and curvature, and panoramic distortion.